Browse all practice questions for the Propane Gas Safety and Installation Certification Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Propane Gas Safety and Installation Certification Practice Test course image
All questions

These questions are part of the practice quiz. Start practicing

  • How is the capacity of an LP-Gas container determined?
  • Which type of valves are prohibited from being located between a pressure relief device and the container unless a listed PRV manifold is used?
  • Aboveground containers with a capacity of 501 to 2,000 gallons should be located what distance from a building?
  • Connections to ASME containers installed underground must be located within what type of structure?
  • Emergency shutoff valves with a fusible element shall have a melting point NOT exceeding what temperature?
  • LP-Gas containers must be protected from damage caused by what?
  • All LP gas containers must have their pressure relief valve in direct communication with which part of the container?
  • What is the minimum distance required for a 1,000-gallon container from another LP-gas container of more than 125 gallons?
  • What is the required vertical clearance above cooking appliances to combustible materials?
  • What type of piping material is limited to vapor service pressures mentioned earlier?
  • How far must one opening commence from the top and bottom according to the Two Permanent Openings Method?
  • What is the term for the air that mixes with flue gases in a draft hood?
  • Which code governs the construction of indirect vaporizers for LP-gas?
  • Under what condition must containers involved in a fire be permanently removed from service?
  • What is required for proper installation of combustion air supply for fuel burning appliances?
  • What type of appliances derive all air for combustion directly from the outside atmosphere?
  • How many non-refillable containers, each with a maximum capacity of 1.08 lb, are permitted for commercial food service appliances?
  • The sniff test to detect odorization should be conducted under which condition?
  • Which of the following is true regarding the maintenance of containers fabricated to earlier regulations?
  • Engines used to drive portable pumps and compressors shall be equipped with __________.
  • Which type of fittings is permitted in concealed locations?
  • Clearances from combustible materials for unlisted air-conditioning appliances must be at least how much?
  • How often must Class I and Class X permit holders attend a sanctioned safety seminar?
  • What is the maximum overall length for flexible metallic connectors used with liquid or vapor piping on stationary containers of 2000 gallon w.c. or less?
  • For a high pressure regulator with an overpressure protection device, what must the device limit the outlet pressure to when the regulator seat disc is removed?
  • In commercial applications, how should ventilating hoods and exhaust systems be installed?
  • Which of the following statements is true regarding the installation of cooking appliances?
  • What main role do protective housings serve for transportable tank systems?
  • Every container built after December 1, 1965, designed to be filled volumetrically must include a:
  • Which device is required to minimize the entrance of water or matter into the relief device or discharge piping?
  • What is the minimum height for exit terminals of mechanical draft systems when adjacent to public walkways?
  • Which aspect of transportation safety is critical when dealing with LP Gas?
  • Indirect vaporizers must be constructed according to the applicable provisions of which code for a design pressure of 250 psig?
  • Where should re-circulating direct gas-fired industrial air heaters NOT be used?
  • A type B-W gas vent must terminate at least how many feet in vertical height above the bottom of the wall frame?
  • What type of valve should equipment connected to a piping system have?
  • Which type of heaters should NOT be installed in or attached to combustible walls unless they are listed for such installation?
  • What is the primary purpose of an overfilling prevention device in LP Gas operations?
  • Which of the following is NOT a permissible fitting type for concealed locations?
  • What type of air should be handled by non-circulating direct gas-fired industrial air heaters?
  • What is the minimum requirement for listed gas-fired toilets to be installed on combustible floors?
  • During minor renovations, the number of containers in a building shall not exceed what?
  • What is the minimum pressure test that should be conducted regardless of the design pressure?
  • What is an important part of the installation of fuel containers?
  • To ensure proper venting, gas vent systems must be installed above which component of a gas appliance?
  • How many feet vertically must a Type B-W gas vent terminate above the bottom of a wall furnace?
  • Hose length at a dispensing station may NOT exceed what length unless otherwise approved?
  • Polyethylene piping systems are limited to vapor service not exceeding which pressure?
  • What should be done with liquid LP-gas in a container that is to be abandoned underground?
  • Metallic pipe joints can be joined how according to safety regulations?
  • Which of the following is essential for securing the stability of a cargo tank vehicle?
  • What is the importance of painting aboveground containers?
  • In which type of occupancies are room heaters prohibited from installation?
  • What is prohibited during public hours in a building undergoing minor renovations concerning propane cylinders?
  • What type of valve should be installed in sections of piping where liquid LP-Gas can be isolated?
  • What should be done after detecting leakage during a gas supply test?
  • Who must be trained when installing polyethylene piping?
  • How many feet must a chimney extend above the highest connected gas appliance?
  • At a motor fuel dispensing station, hose length may NOT exceed what without AHJ approval?
  • What type of foundation should all dispensers be installed on?
  • What is required to prevent damage to the building structure or appliances and equipment?
  • What is the proper location for exhausting Type 1 and Type 2 clothes dryers?
  • What must be ensured regarding the number of propane cylinders and workers in a building?
  • What must be done to fuel containers to prevent them from becoming loose?
  • Containers, other than aluminum, must be what after being involved in a fire and showing no distortion?
  • What is the main risk associated with an improper sediment trap installation?
  • Why is odorizing LP gases important before delivery?
  • When two or more vent connectors enter a common vent, which connector should enter at the highest level?
  • How many months after the renewal date can a semi-annual permit be issued?
  • A system being leak tested should not show any change in pressure for how long?
  • In case of an incident involving LP-gas systems, the dealer must notify the LP gas administrator __________.
  • What is the maximum water capacity for LP-gas containers used on passenger carrying vehicles?
  • What must be installed where a nonmetallic gas hose connector is attached to the building piping?
  • Which type of regulator is designed for lower pressure LP-Gas applications?
  • Changes in direction of gas pipe must be made using which items?
  • A Class X manager shall be considered actively supervising if present at the base of operation at least ________ of the reasonably normal hours.
  • What is the maximum weight for portable refillable LP-gas cylinders not filled on site to require a warning label?
  • Which of the following is NOT a method of closing an emergency shutoff valve?
  • What is the minimum clearance to combustible materials for unlisted suspended-type unit heaters?
  • For each Class X Manager's examination, how many questions shall be drawn from the reservoir?
  • What is the duration of the warranty required for new propane containers sold or installed in Oklahoma?
  • What must be done to determine compliance with code requirements before operating newly installed gas piping?
  • What is the minimum vertical distance that must be maintained from mechanical draft vents to any door or operable window?
  • Which appliances are NOT required to have venting?
  • Indirect atmospheric-type vaporizers with a capacity of less than 1 quart are NOT required to be equipped with what?
  • Excess flow valves in propane systems are designed with a bypass not to exceed what size opening?
  • What regulatory guidance governs the labeling of vehicles that transport LP Gas cylinders?
  • What should portable DOT containers designed to be filled by weight be marked with?
  • How should air be supplied to industrial air heaters?
  • What type of gas piping would require the removal of permanent construction to access?
  • Single-wall metal pipes should not pass through which of the following?
  • What is the minimum cover depth required over all underground metallic piping?
  • What is the condition for aboveground containers?
  • What is the restriction regarding the passage of single-wall metal pipe vent connectors through ceilings, floors, or walls?
  • The maximum design operating pressure for indoor piping systems should not exceed what value unless welded?
  • Which type of copper tubing is acceptable for propane installations?
  • Where should the sediment trap be installed relative to the equipment?
  • Which organization’s standards should containers be designed, fabricated, tested, and marked in accordance with?
  • A regulator's casings should not use non-metallic parts for what reason?
  • What characterizes a Category I vented appliance?
  • How should piping in systems be run for efficient operation?
  • What is the minimum clearance required on all sides and the rear for an unlisted pool heater?
  • Which type of pipe fittings should not be used for metallic pipelines and tubing?
  • What is a potential hazard of improperly installed venting systems?
  • What is a fixed liquid level gauge that indicates the maximum permitted filling limit of a container?
  • Integral two-stage regulators shall NOT incorporate which feature in the high-pressure regulator portion?
  • What is the status of containers fabricated before April 1, 1967, that have been maintained and requalified?
  • What is the minimum design pressure required for ASME containers installed in enclosed spaces on vehicles?
  • In a gas appliance installation, how should the vent connector be configured?
  • Brazing filler material for tubing joints shall have a melting point exceeding which temperature?
  • What is the required slope for piping in a system where vapor condensation can occur?
  • Before a piping installation is accepted for operation, what must be done?
  • Which of the following should NOT be used to test for gas leakage?
  • What must be provided for Type 2 clothes dryers to allow for proper functioning?
  • What is the lower flammability limit of propane vapor?
  • What is the purpose of a safety shutoff device?
  • Which type of gas appliances are allowed to be vented to atmospheres other than inside?
  • The installation of which component is prohibited inside an elevator shaft?
  • What is the required separation distance for more than one container used for training in the same room?
  • What is the initial boiling point of commercial propane at 14.7 psia?
  • In gauging devices requiring the bleeding of product to the atmosphere, what is the maximum bleed valve opening size to the atmosphere?
  • When should back flow check valves close?
  • All bulk storage of ____ gallons and above must be labeled with the contents and a "NO SMOKING" sign.
  • Which component is NOT a part of safe propane gas installation?
  • Where must the pressure relief valve of all containers be positioned?
  • What must be used to secure a vehicle transporting LP Gas when parked?
  • What is the primary design requirement for forced draft systems under positive pressure during operation?
  • What is the primary function of a "NO SMOKING" sign in areas where LP-gas is stored?
  • What is the minimum distance a single 1,000-gallon aboveground container must be installed from any building?
  • Within how many years should the pressure relief valve be replaced for cylinders used in industrial truck service?
  • Which of the following is essential for ventilation in space with combustion appliances?
  • Which of the following is NOT a reason for filling a container with water or inert gas before abandonment?
  • Who administers and enforces the National Fuel Gas Code?
  • What is crucial to maintain the integrity of a gas control system?
  • Buildings that are not fire resistive should be located how far from a point of transfer?
  • What is the role of the equipment shutoff valve in gas piping systems?
  • Which statement accurately reflects the requirement for containers placed outdoors?
  • Which type of gas vent is preferred for high-efficiency appliances?
  • What condition must DOT cylinders meet before they can be refilled or transported?
  • What is a necessary item to carry in a cargo tank vehicle during loading or unloading?
  • What type of permit is required for a person actively managing LP Gas operations?
  • What must be followed for the operation of the automatic main gas control valve and other electrical devices?
  • When is it permissible to refill a DOT cylinder?
  • Where should ASME containers and cylinders not be stored or transported?
  • When operating cooling and heating equipment simultaneously, what is permissible?
  • In an emergency shutoff system, what function does a fusible element serve?
  • What is required to fill or purge a container that will be abandoned underground?
  • What does the term 'placarded' refer to in the context of transporting cylinders?
  • Where should ASME connections for pressure relief valves be installed?
  • What is the minimum distance equipment with a draft hood must be from combustible material when installed in a single-wall metal pipe?
  • Where should a gas vent extending through an exterior wall NOT terminate?
  • What should not be done to temperature sensitive elements of emergency shutoff valves?
  • Which type of venting system must listed vented wall furnaces use?
  • What type of valve must be installed at the discharge end of the transfer hose at vehicle fuel dispensers?
  • What should be done to annular spaces around penetrations for vents and combustion air intake pipes?
  • Which permit allows a holder to engage in any phase of the LP Gas business?
  • If a safety shutoff device is not functioning properly, what should be done?
  • What does the overfilling prevention device NOT serve as?
  • Which material shall NOT be used for upper and lower casings of regulators?
  • What is necessary for indoor combustion air supply?
  • How much higher must a chimney extend compared to any building portion within 10 feet?
  • What is essential for maintaining the structural integrity of installations?
  • If outside, piping shall be installed under the vehicle and positioned where?
  • Gas piping should not be installed through which of the following to avoid safety hazards?
  • Cylinders with water capacities greater than __________ shall NOT be located on decks or balconies of multi-unit dwellings above the first floor.
  • What term describes the additional air that is not required for combustion but enters the system?
  • Vehicles transporting cylinders over 1000 lb must be labeled according to which regulations?
  • How should mechanical draft systems be classified?
  • What is the purpose of dilution air?
  • According to NFPA 82, which type of equipment must be vented?
  • According to the standard method, what is the minimum volume of combustion air required?
  • Mechanical draft venting systems must terminate at least how many feet below any door or operable window?
  • Which device is critical for preventing the overfilling of LP Gas cylinders?
  • Listed floor-mounted food service equipment must be installed at least how far from combustible material?
  • What is the preferred method of connecting any appliances to venting systems?
  • What is a primary concern when using portable heaters in relation to safety?
  • What is a key requirement for the installation of gas appliances?
  • What is the minimum cover required for polyethylene and polyamide piping installed outside and underground?
  • Equipment used with LP-gas should be fabricated from materials that are what?
  • How many pressure relief devices must ASME containers be equipped with at a minimum?
  • What should be done if a pilot flame goes out in a gas appliance?
  • What is the safe practice after a pressure test shows no leakage?
  • Is the installation of lightning protection equipment required on LP-Gas storage containers?
  • What permit allows the holder to transport LP Gas as a common or private carrier?
  • What is the key purpose of exhaust system spark arresters in engines driving portable pumps?
  • Which insurance is NOT required from an applicant for a Class I Dealer permit?
  • What is the required slope for a vent connector during installation?
  • What is the recommended spacing for supports of 3/4" or 1" steel pipe?
  • ASME containers with more than 2,000 gallons water capacity must have an opening for what?
  • What is the maximum operating pressure for piping that contains liquid LP-gas and requires hydrostatic relief valves?
  • What type of pressure relief valve is required for DOT and ASME engine fuel or mobile containers?
  • What should not be present in any portion of a venting system?
  • What device must gas fired heating appliances have to manage gas flow if the pilot flame goes out?
  • The class of permit that allows a holder to transport LP Gas to producers or distributors is known as what?
  • What safety measure is advised for the installation of gas appliances in confined spaces?
  • When abandoning a container underground, what should be used to remove remaining gas vapor?
  • A cylinder shall ________ if it is NOT suitable for continued service.
  • What is needed to protect underground metallic piping against soil conditions?
  • For what reason must containers that have been in a fire be requalified?
  • How should emergency shutoff valves be maintained?
  • What is the primary safety concern with cylinders used in experimental purposes when manifolded?
  • A chimney for residential-type gas appliances must extend at least how many feet above the roof where it passes through?
  • Which is an acceptable medium for pressure testing?
  • Which component is essential for maintaining safety in the event of a fire?
  • When is the outlet pressure of the second-stage regulator limited to 2.0 psig?
  • Which device should NOT be disregarded in terms of LP Gas safety?
  • What is a consequence of inadequate clearance of venting systems around obstructions?
  • In what situation may the authority having jurisdiction retroactively apply portions of the code?
  • What is the minimum height that a chimney must extend above the highest connected equipment draft hood outlet?
  • What connects a fuel gas burning appliance to a vent or chimney?
  • What is the minimum bulk propane storage capacity required for Class I permit holders?
  • What kind of installation protection is mandatory for water heaters?
  • For installations of a tank heater of 500 gallons water capacity or less, what is the minimum required distance from external exposures?
  • What type of modifications or installations require that gas pipe access must generally be direct and easy?
  • What is the maximum allowable flow area for a vertical vent compared to the listed appliance vent area or draft hood outlet?
  • What is a defining characteristic of a type B-W gas vent?
  • What is the maximum horizontal length for a vent connector for each inch of connector diameter?
  • What type of protection should be provided for connections to underground ASME containers?
  • Cylinders used for training purposes in the same room must be separated by what minimum distance if more than one container is present?
  • What type of fuel connection is prohibited between a tractor and another vehicle?
  • During a pressure test for a single-family dwelling, the system should show no change in pressure for how long?
  • Gas piping serving heating appliances is allowed to also serve what other equipment?
  • When locating containers outside buildings, they must be positioned with respect to which of the following?
  • Regulators for outdoor installations must be designed to prevent what?
  • What is the primary function of a pressure relief device in an ASME container?
  • Field welding on propane containers is limited to attachments on which parts?
  • What type of equipment must be coated or protected to minimize corrosion when buried or mounded?
  • What score is required to pass all examinations in this certification program?
  • What is the minimum required distance between propane containers with a water capacity of 501 to 2,000 gallons?
  • Gas piping inside any building is prohibited from being installed in which of the following spaces?
  • What type of protection must be used to safeguard the appurtenances of cylinders with a water capacity of 1,000 lbs or less?
  • What should be included in a water heater installation?
  • From what point should distances for all underground or mounded ASME containers be measured?
  • What type of draft is produced by the difference in weight between flue gases and outside air?
  • What benefit do shielded ignition systems provide for engines used with LP-gas?
  • Is it permissible to stack containers one above the other?
  • Sparks from what component can be a fire risk in LP-gas systems?
  • What must direct-fired vaporizers be permanently marked with?
  • If a gas piping system displays a pressure decrease, what does it indicate?
  • What is the maximum internal diameter for transfer hoses used for connections to individual containers being filled indoors?
  • What type of compound must be resistant to the action of liquefied petroleum gas?
  • The distance measured horizontally from the point of discharge of a container pressure relief valve to any building opening must follow what?
  • What is the minimum distance required between a point of transfer and mainline railroad track centerlines?
  • What is the term for the amount of water required to fill a container at 60 degrees F?
  • What is the purpose of a quick-acting shutoff valve at the discharge end of fuel dispensers?
  • Portable heaters must have an approved device to shut off gas in case of what event?
  • A cylinder with an expired requalification date shall NOT be refilled until it is requalified by the methods prescribed in DOT regulations. What must be ensured regarding such a cylinder?
  • What does a 'natural draft' in gas systems primarily rely upon?
  • What must be provided to prevent boiler steam pressure from exceeding safe limits?
  • Single-wall metal pipe must extend at least ______ above the highest point where it passes through a roof.
  • In cold climates, uninsulated single-wall pipe shall NOT be used for what purpose?
  • When can a vent connector be connected to a chimney flue serving a fireplace?
  • What type of permit is specifically designated for managing LP Gas?
  • What is the maximum propane capacity allowed for containers used in a public building during minor renovations?
  • What is commonly referred to as a vessel used for transporting or storing LP-Gases?
  • How high must a chimney for medium-heat equipment extend above a building?
  • Which type of devices are crucial for controlling hazards in steam and hot water boilers?
  • LP-gas containers should not exceed certain limits for safety. What is the maximum allowed capacity for containers on passenger vehicles?
  • What is the minimum distance a draft hood's relief opening should be from any surface?
  • A 350-gallon container installed alongside a building must be how far from the portion of the building that projects out?
  • What action should be taken immediately after turning on the gas in a new system?
  • What is the minimum water capacity for tanks that require protective measures against physical damage?
  • What is the status of installing containers on the roof of a structure?
  • What is essential to have in place to prevent gas flow in a portable heater?
  • What is true about the types of gas appliances allowed in healthcare facilities?
  • How should the safety of transporting LP Gas be ensured according to regulations?
  • How should cooking appliances be installed in relation to the cooking top or oven racks?
  • For venting purposes, what is a critical height for gas vent termination above the building structure?
  • The cross-sectional area of the common vent must be equal to or greater than what?
  • What is a compartment or chamber connected to ducts that forms part of the air distribution system called?
  • What is the minimum vertical distance required between food service hot plates and combustible materials?
  • What is the maximum outlet pressure setting for single-stage regulators?
  • How many means of closing must emergency shutoff valves have?
  • Which of the following is NOT allowed with re-circulating systems in dangerous environments?
  • What is the maximum capacity for individual LP-gas containers used on non-passenger carrying vehicles?
  • What gas should a new piping system NOT be tested with?
  • What action should be taken if leakage is indicated during a pressure test?
  • All Class I permit holders must have a current copy of _____________ on file at each branch.
  • Where is the transfer of liquid into containers mounted on vehicles prohibited?
  • Which organization’s approval is necessary for the installation of containers on roofs?
  • In what conditions should polyethylene piping typically be installed?
  • What should be replaced when a flanged joint is opened?
  • Where should appliances be located to ensure proper circulation?
  • What concentration in air is the limit for odorizing LP gases prior to delivery?
  • What happens if liquid LP-Gas pressure develops between shutoff valves?
  • What do we call the extra air that passes through the combustion chamber beyond what is needed for complete combustion?
  • Which of the following is NOT a requirement for a cargo tank vehicle in LP Gas operations?
  • ASME code is primarily concerned with which area?
  • Which type of piping is permitted for use when working with LP-Gas?
  • What action must be taken regarding vent connectors in relation to fireplaces?
  • What is the minimum individual water capacity for fixed installations that requires plans to be submitted for approval?
  • What is a critical safety requirement for underground abandoned containers?
  • What must indirect vaporizers be equipped with to prevent liquid from passing through?
  • If cylinders used in industrial settings are manifolded together, what is the maximum total propane capacity allowed?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy